Channel-Physical

Manning's n is not a property of a channel but a property of the cross-section nodes along the channel. The cross-section defines the shape and other physical properties of the channel (except for length). The properties between two cross sections are interpolated. For more information, see "Cross Section—Physical" .

Channel-Physical Attributes

Attribute Description
Flow (Maximum User Defined) Maximum flow allowed in link. Use 0.0 if not applicable.
Invert (Start) The start, or upstream, invert of the currently highlighted element.
Set Invert to Stop Node Sets the stop invert of the current element to the elevation of the stop node (downstream). Set this to False to enter a value for the elevation of the invert, or set this field to True to use the stop-node elevation.
Invert (Stop) The stop, or downstream, invert of the currently highlighted element.
Slope The difference between the start invert and stop invert divided by the length of the channel. This is a calculated results field and is not editable.